 TOwer 8 mm Galvanised Steel
 TOwer 8 mm Galvanised Steel| Dimensions | Lenght : 10,50 metres Diameter : 51 cm Wheight : 1300 kg | 
| Access | Trap doors for transmission maintenance. | 
| Vibration sensor | Integrated. | 
| Anemometer | Standard (Better protection against wind gusts). | 
| Solar panel | Standard (For maintenance purposes, recharge the battery when the panel is not used). | 
| Decelerators | Superior : rotation completes in 4m30s Inferior : centrifuge clutch - 10-inch diameter. | 
| WARRANTY | 10 years (except for the clutch). | 

 2 or 4 blade propeller Carbon fiber
 2 or 4 blade propeller Carbon fiber| Lenght | 5,40 to 5,70 meters | 
| Rotational speed | 585 rot/min | 
| Modelling | In a 3D virtual environment. | 
| Stability | Dynamic balance for oscillations | 
| 4 blade propellers | - 50 % noise pollution | 

 Motor > volvo penta diesel tad541-ve
 Motor > volvo penta diesel tad541-ve| Power | 175 HP (129 KW) | 
| Model | 4 cylinders - 5.0 litres | 
| Torque / Power | 810 Nm / 1800-2200 tpm | 
| Injection | Direct - Diesel Common Rail. Electronic control / Liquid cooling. | 
| Tank | 740 litres (under the engine) Locked against vandalism. | 
| Consumption | 26 l/h | 

 Enclosure
 Enclosure| Galvanised sheet-metal 1,5 - 3 mm | |
| Access | Easy access on all sides of the engine via 4 doors and a security locking system. | 
| Resistance | Extreme conditions | 
| Option | Connected alarm (SMS) + siren | 

 OPERATION SYSTEM > deepsea
 OPERATION SYSTEM > deepsea| start / stop | Automatic. The user adjusts the starting temperature | 
| LCD screen | Parameter control while the engine is running. | 
| Temperature sensors | Lower, at the ground level + Upper, in the upper part of the tower | 
| Tracing / Contrôle | Remote diagnosis via smartphone or PC (SIM card subscription). | 
* Theoretical layout under the influence of air mass, with positive thermal inversion, air humidity of 75%, non-dry soils, without winds, with sufficient heating, within the limit of a white frost of -2.5°C. This document has only an indicative and non-contractual informative value, not engaging the responsibility of RN7AS, nor the results obtained.